Magellan MG-6060 Manual de instalación Pagina 1

Busca en linea o descarga Manual de instalación para Los Sistemas De Control De Acceso De Seguridad Magellan MG-6060. Magellan MG-6060 Installation manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Model #: MG-6060

All-In-One Wireless Security System V1.0Model #: MG-6060Reference and Installation Manual

Pagina 2

8 Reference & Installation ManualHardwire Zone ConnectionsMagellan comes with two on-board hardwire zones. You can connect hardwire detection dev

Pagina 3 - Table of Contents

Paradox Magellan Systems 9X10 Transmitter ConnectionMagellan supports the X10 communication protocol. X10 is a communication protocol for remote con

Pagina 4

10 Reference & Installation ManualFigure 12: Mounting Magellan onto the Wall PlateFigure 13: Magellan’s Back PlateMounting Magellan on the WallMa

Pagina 5 - Introduction

Paradox Magellan Systems 11Programming MethodsWinLoad Installer Upload/Download SoftwareProgram the Magellan console remotely or on-site using the W

Pagina 6 - Quick Setup

12 Reference & Installation ManualUser CodesA person must be assigned to a User code in order to have access to Magellan. A User code defines the

Pagina 7 - 7.Time and Date

Paradox Magellan Systems 13Zone ProgrammingMagellan supports up to 16 wireless zones whereby each zone can be configured with a different zone defin

Pagina 8 - Installation

14 Reference & Installation ManualFollow/Stay ZonesSections [001] to [016]: Zones 1 to 16, 3-digit # = 004Follow/Stay zones function as follows:•

Pagina 9 - Programmable Outputs (PGMs)

Paradox Magellan Systems 1524Hr. Gas ZonesSections [001] to [016]: Zones 1 to 16, 3-digit # = 012When a 24Hr. Gas zone opens, whether it is armed or

Pagina 10 - Connection

16 Reference & Installation Manual• During the Intellizone Delay, a second zone has caused an alarm.• During the Intellizone Delay, the zone in a

Pagina 11 - Location and Mounting

Paradox Magellan Systems 17Wireless ProgrammingThe Magellan system supports up to 16 wireless zones and two wireless doorbells. These wireless zones

Pagina 13 - Programming Methods

18 Reference & Installation Manual• “Weak”: This is the weakest reading. The transmitter should be moved to another location. Sometimes moving th

Pagina 14 - User Codes

Paradox Magellan Systems 19Table 5: MG-REM2 Remote Control Button Programming[172] 12______ ______ ______ ______012[173] 13______ ______ ______ ____

Pagina 15 - Zone Programming

20 Reference & Installation ManualFigure 19: Remote Control Button Options* = Hex values A to F are keys [1] to [6] from Magellan’s Center Keypad

Pagina 16

Paradox Magellan Systems 21Arming and DisarmingRegular Arming Switches to Stay ArmingSection [092]: Option [4]Option [4] OFF = Regular arming switch

Pagina 17 - Zone Options

22 Reference & Installation ManualOne-Touch ArmingSection [092]: Options [7] and [8]Option [7] OFF = One-touch Regular/Force arming disabledOptio

Pagina 18 - EOL (End-Of-Line) Zones

Paradox Magellan Systems 23Alarm OptionsBell Cut-off TimerSection [063]: 001 to 255 minutes; 000 = Disabled; Default = 4 minutesAfter an audible ala

Pagina 19 - Wireless Programming

24 Reference & Installation ManualTable 7: Tamper Recognition OptionsTamper Bypass OptionsSection [094]: Option [5]Option [5] OFF = Ignore any ta

Pagina 20 - Assigning Remote Controls

Paradox Magellan Systems 25Reporting and Dialer SettingsReport CodesA report code is a 1- or 2-digit hexadecimal value consisting of digits from 1 t

Pagina 21

26 Reference & Installation Manual• Fire Panic: Panic keys [7] and [9] (see page 24) or the appropriate button(s) on a remote control (see page 1

Pagina 22

Paradox Magellan Systems 27Monitoring Station Telephone Numbers (MSTNs)Section [111] = Monitoring Station Telephone Number 1Section [112] = Monitori

Pagina 23 - Arming and Disarming

Paradox Magellan Systems 1Table of ContentsIntroduction... 3About Magellan and this Manual...

Pagina 24

28 Reference & Installation Manual4. Press [NEXT] until the desired telephone number appears, then press [OK].5. Enter the desired telephone numb

Pagina 25 - Alarm Options

Paradox Magellan Systems 29Section [102]: Options [1] to [3]; SpecialOption [1] ON = Call MSTN 1Option [2] ON = Call MSTN 2Option [3] ON = Call Page

Pagina 26 - Panic Alarms

30 Reference & Installation ManualTable 11: Telephone Line Monitoring OptionsPlease note that when the dialer detects an incoming call, the TLM t

Pagina 27 - Reporting and Dialer Settings

Paradox Magellan Systems 31Programmable OutputsA PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM will clos

Pagina 28 - Console Telephone Numbers

32 Reference & Installation ManualSystem SettingsSoftware ResetSection [201]Performing a software reset will reset all programmed sections back t

Pagina 29 - Utility Reporting

Paradox Magellan Systems 33* When a communication failure trouble is acknowledged by pressing [OK], you will be given the option to call your servic

Pagina 30 - Event Call Direction

34 Reference & Installation ManualWinLoad Software SettingsPanel Answer OptionsThe following two options define how Magellan answers an incoming

Pagina 31 - Paradox Magellan Systems 29

Paradox Magellan Systems 35Appendix 1: Automatic Report Code ListSystem Event Default Contact ID Report Codewhen using sections [790] to [795]Defaul

Pagina 32 - TLM Fail Timer

36 Reference & Installation ManualAC Failure 1 3A1 - AC loss AT - AC TroubleBattery Failure 1 3A9 - Battery test failure YT - System Battery Trou

Pagina 33 - Programmable Outputs

Paradox Magellan Systems 37Appendix 2: Ademco Contact ID Report Code ListCID# Reporting Code Programming ValueMedical Alarms - 100100 Medical alarm

Pagina 34 - System Settings

2 Reference & Installation ManualWinLoad Software Settings ... 34Panel Answer Options ...

Pagina 35

38 Reference & Installation ManualCID# Reporting Code Programming Value335 Local printer paper out 54336 Local printer failure 55337 Expansion mo

Pagina 36 - WinLoad Software Settings

Paradox Magellan Systems 39CID# Reporting Code Programming Value525 Reversing relay disabled AE526 Notification appliance chk. #3 disabled AF527 Not

Pagina 37

40 Reference & Installation ManualIndexNumerics001 to 016 ...13–16021 to 036 ...

Pagina 38

Paradox Magellan Systems 41Arming optionsAuto-arm options ...21Bell Squawk on Arm/Disarm with Re

Pagina 39

42 Reference & Installation ManualEEntry Delay 1 ...13Entry Delay 2 ...

Pagina 40

Paradox Magellan Systems 43Special disarming ...25System trouble ...

Pagina 41

44 Reference & Installation ManualSystem master code ...12User code length ...

Pagina 42

Paradox Magellan Systems 45

Pagina 43 - Paradox Magellan Systems 41

46 Reference & Installation ManualWARRANTYParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and

Pagina 45 - Paradox Magellan Systems 43

Paradox Magellan Systems 3IntroductionAbout Magellan and this ManualMagellan is designed for fast and easy installation. Simply remove it from the bo

Pagina 46

780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADATel.: (450) 491-7444 Fax: (450) 491-7313www.paradox.caPrinted in Canada - 11/2004 MAGELLAN

Pagina 47 - Paradox Magellan Systems 45

4 Reference & Installation ManualQuick SetupFollow these steps to quickly set up Magellan with the required settings for a basic security install

Pagina 48 - FCC WARNINGS

Paradox Magellan Systems 5When you are done the next menu option will appear. Press [NEXT] until you see the “Passwords” menu or press the [8] key t

Pagina 49

6 Reference & Installation ManualInstallationAC PowerMagellan requires a 9Vac (1A) or 16.5Vac (1A) transformer (not included) to supply power to

Pagina 50

Paradox Magellan Systems 7For UL compliant installations, the Magellan console must be able to seize the telephone line and place a call in an emerg

Comentarios a estos manuales