22 Programming Guide
Appendix 4: Ademco Contact ID Report Code List
CID# Reporting Code Programming
Value
CID# Reporting Code Programming
Value
CID# Reporting Code Programming
Value
Medical Alarms - 100 151 Gas detected 26 327 Notification appliance chk. #4 4E
100 Medical alarm * 01 152 Refrigeration 27 System Peripheral Troubles - 330 and 340
101 Pendant transmitter 02 153 Loss of heat 28
330 System peripheral 4F
102 Fail to report in 03 154 Water leakage 29
331 Polling loop open 50
Fire Alarms - 110 155 Foil break 2A 332 Polling loop short 51
110 Fire alarm 04 156 Day trouble 2B 333 Expansion module failure 52
111 Smoke 05 157 Low bottled gas level 2C
334 Repeater failure 53
112 Combustion 06 158 High temperature 2D
335 Local printer paper out 54
113 Water flow 07 159 Low temperature 2E 336 Local printer failure 55
114 Heat 08 161 Loss of air flow 2F 337 Exp. module DC loss 56
115 Pull station 09 162 Carbon monoxide detected 30
338 Exp. module low battery 57
116 Duct 0A
163 Tank level 31 339 Exp. module reset 58
117 Flame 0B Fire Supervisory - 200 and 210 341 Exp. module tamper 59
118 Near alarm 0C 200 Fire supervisory 32 342 Exp. module AC loss 5A
Panic Alarms - 120 201 Low water pressure 33 343 Exp. module self-test fail 5B
120 Panic Alarm 0D 202 Low CO
2
34 344 RF receiver jam detect 5C
121 Duress 0E 203 Gate valve sensor 35 Communication Troubles - 350 and 360
122 Silent 0F 204 Low water level 36 350 Communication 5D
123 Audible 10 205 Pump activated 37 351 Telco 1 fault 5E
124 Duress - Access grated 206 Pump failure 38 352 Telco 2 fault 5F
125 Duress - Egress granted 12 System Troubles - 300 and 310 353 Long range radio 60
Burglar Alarms - 130 300 System trouble 39 354 Fail to communicate 61
130 Burglary 13 301 AC loss 3A 355 Loss of radio supervision 62
131 Perimeter 14 302 Low system battery 3B 356 Loss of central polling 63
132 Interior 15
303 RAM checksum bad 3C 357
Long range radio VSWR prob.
64
133 24-hour
16
304 ROM checksum
3D Protection Loop Troubles - 370
134 Entry/Exit
17
305 System reset
3E
370 Protection loop
65
135 Day/Night
18
306 Panel program changed
3F
371 Protection loop open
66
136 Outdoor
19
307 Self-test failure
40
372 Protection loop short
67
137 Tamper
1A
308 System shutdown
41
373 Fire trouble
68
138 Near alarm
1B
309 Battery test failure
42
374 Exit error alarm
69
139 Intrusion verified
1C
310 Ground fault
43
375 Panic zone trouble
6A
General Alarms - 140
311 Battery missing/dead
44
376 Hold-up zone trouble
6B
140 General alarm
1D
312 Power supply over current limit
45
377 Swinger trouble
6C
141 Polling loop open
1E
313 Engineer reset
46
378 Cross-zone trouble
6D
142 Polling loop short
1F Sounder/Relay Troubles - 320 Sensor Troubles - 380 and 390
143 Expansion module failure
20
320 Sounder/relay
47
380 Sensor trouble
6E
144 Sensor tamper
21
321 Bell 1
48
381 Loss of supervision - RF
6F
145 Expansion module tamper
22
322 Bell 2
49
382 Loss of supervision - RPM
70
146 Silent burglary
23
323 Alarm relay
4A
383 Sensor tamper
71
147 Sensor supervision failure
24
324 Trouble relay
4B
384 RF transmitter low battery
72
24-hour Non-burglary - 150 and 160
325 Reversing relay
4C
385 Smoke detector Hi sensitivity
73
150 24-hour non-burglary
25
326 Notification appliance chk. #3
4D
386 Smoke detector Low sensitivity
74
Comentarios a estos manuales