Page 12
System Setup: Outputs (PGMs)
4. Press one of the
following:
edit: press to assign the
alarm activation to areas 1, 2, or both.
next: press, select one of the following, and then press ok:
Steady on alarm
Pulse on alarm
ON for 1 sec.
ON for 5 sec.
ON for 15 sec.
ON for 30 sec.
ON for 1 min.
ON for 5 min.
ON for 15 min.
ON for 30 min.
5. Once complete, choose whether to set-up remote access
(see Set-up Remote Access on page 10).
Custom Setup of PGMs
1. Press ok.
2. Press next.
3. Select Custom Setup,
then press ok.
4. Using the keypad, enter
the following for output
1:
Event number
Sub-event number
Partition number
Refer to the MG6250 Section Programming Guide for the
complete list of MG6250 events and sub-events.
NOTE: For sections [0321] to [0328], the first set of
0s (00-00-0) correspond to activation events; the second set, to
deactivation events. Press # at any time to quickly access the
next programmable section. In addition, press and hold 0 for
three seconds to exit any menu, at any time.
5. Enter the PGM options for
output 1.
Area?
edit next back
1
Activation Type
ok back
Remote Access?
ok next back
Custom Setup?
ok next back
[0321]
00-00-0//00-00-0
PGM
Event number
Sub-event number
Partition number
[0341]
(********)
PGM
Vista de pagina 11