16 Reference & Installation Manual
5.1.11 Instant Fire Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 11
when a Instant Fire zone opens, whether it is armed or disarmed, the console will send the corresponding Alarm
Report Code and the alarm is always audible regardless of other settings. Fire alarms generate an intermittent (pulsed)
bell/siren output signal as shown in Figure 10 on page 16.
Figure 10: Bell/Siren Output during a Fire Alarm
5.1.12 Delayed Fire Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 12
When a Delayed 24Hr. Fire zone opens, whether it is armed or
disarmed, the console will react as shown in Figure 11. Delayed
24Hr. Fire zones are commonly used in residential homes where a
smoke detector often generates false alarms (i.e., burning bread,
etc.). Fire alarms generate an intermittent (pulsed) bell/siren output
signal as shown in Figure 10 above.
5.1.13 Instant Fire Silent Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 13
When a Instant Fire Silent zone opens, whether it is armed or
disarmed, the console will generate the following:
The console can send the corresponding Alarm Report Code and
the alarm will be silent regardless of other settings.
5.1.14 Delayed Fire Silent Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 14
When a Delayed Fire zone opens, whether it is armed or disarmed,
the console will react as shown in Figure 11. Delayed 24Hr. Fire
zones are commonly used in residential homes where a smoke
detector often generates false alarms (i.e., burning bread, etc.).
The console can send the corresponding Alarm Report Code and
the alarm will be silent regardless of other settings.
5.1.15 24 Hr. Buzzer
Sections [001] to [032]: Zones 1 to 32, First Digits = 15
When a 24Hr Buzzer Zone opens, whether the zone is armed or
disarmed, the control panel sets off the keypad’s buzzers to
indicate that the zone was breached. The control panel will report
the alarm, but will not enable the bell/siren output. Enter any valid
access code on the keypad to stop the buzzer. This zone definition
is particularly useful when a user wishes to be notified when
something such as a safe or locker within the home has been
accessed
(i.e. a child accessing a valuable collection).
5.1.16 24 Hr. Burglary Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 16
when a 24Hr Burglary Zone opens, whether the system is armed or disarmed, the control panel will immediately
generate an alarm. This alarm is defined by the alarm type, configured in Zone Programming under zone options [4]
and [5]. See Alarm Types on page 18.
Figure 11: Delayed 24Hr Fire Zone