MG5000 3
Figure 2: Magellan MG5000 Control Panel Overview
Refer to Single Zone
Inputs on page 6
Refer to AC Power
on page 2.
For the keypad’s zone
configurations, refer to page 6.
If EOL is enabled: see section
[706] option [2]. Also refer to
Keypad Zone Connections on
page 6.
AUX Power
Refer to transformer requirements on page 2 for Aux. Power
Output. To connect additional wiring to auxiliary power, use
the red (+) and black (-) keypad connectors. Auxiliary power
will shut down if current exceeds 1.1A. If the auxiliary output
is overloaded and is shut down, you must disconnect all
loads from the output for at least 10 seconds before
reconnecting any load back to the auxiliary output.
To provide maximum lightning protection
we strongly recommend having separate
earth connections for the dialer and zone
ground terminals.
To metallic
enclosure
Ground
clamp
AWG#14 single
conductor solid
copper wire
Cold water
pipe
grounding
The "
BELL" output will
shutdown if the current
exceeds 3A.
Warning:
Disconnect
telephone line
before servicing.
Four pin connector
can be used for
quick installation of a
MG5000 keypad.
Warning:
Do not cut, bend or
alter the antennas
and ensure that
electrical wires do
not cross over the
antennae, as this
may affect signal
reception.
Paradox Memory
Key (PMC-3,
PMC-4)
Antennas"RX" & “TX” LED:
Flashes quickly when
receiving or transmitting
RF signals from
wireless devices.
"STATUS" LED:
Flash once every second = Normal
Flashes ON 1 second and OFF 1 second =
Any trouble
Always ON = Panel is using phone line
Fast flash 6 seconds after power up = Installer
lock enabled
This equipment must be installed and
maintained by qualified service personnel only.
For UL and C-UL warnings, refer to the UL and
C-UL Warnings section at the back of the
MG5000 Reference & Installation Manual.
Used for In-Field Firmware upgrade
through a 306USB Direct Connect
Interface. See Connecting Magellan
to Winload on page 45 for details.
Coming soon: VDMP3 plug-
in voice module for voice
reporting
Press and hold the RESET
button for five seconds. The
STATUS LED will start
flashing. Within 2 seconds
of this flashing, press the
reset switch again. The
panel will reset to default
and restart.
The sum of the
current drawn
from the BELL and
AUX must be
limited to 1.3A
(40VA transformer
strongly
recommended).
Connection for Self-Contained Bell/Siren
Warning:
Max. amount of keypads = 15 keypads
Max. current = 700 mA
Max. distance of keypad from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
Charging and
Battery test LED
Exceeding this limit will overload the panel power supply
and lead to complete system shutdown.