42 Reference & Installation Manual
Part 11: System Settings
11.1 Version Number Display
Enter section [980] to view the version number of the panel. The first digit will appear. Press [ENTER] to scroll through each
consecutive digit (the keypad will beep twice after every digit in the version number). Once the version number has been fully
displayed, an acknowledgement beep (3 beeps) will sound and the first digit will be displayed again.
11.2 Push Button Power Reset
Performing a hardware reset will set all control panel settings to factory default except for the Panel ID and PC Password. Also,
the event buffer will not be erased. To perform a push button power reset:
Press and hold the RESET switch for five seconds. The STATUS LED will start flashing fast. Within 2 seconds of this flashing,
press the reset switch again. The panel will reset to default and restart
11.3 Installer Lock
Section [395]
000 = Disabled, 147 = Lock Enabled, Default = Disabled
Program 147 into section [395] to lock all programming. Performing a hardware reset will not affect the current panel settings. To
remove the Installer Lock, enter 000. Please note that three seconds after turning on the control panel the
STATUS LED and the
relay on the control panel will flash fast for 6 seconds to indicate that the installer lock is enabled. Once enabled, the panel cannot
be reset.
11.4 Keypad Lockout Feature
Sections [864]
If a consecutive number of invalid codes are entered into a keypad, the control panel can be set to deny access from all keypads
for a specified period and send the report code programmed in section [864]. Program the number of consecutive invalid codes
from 001 to 255 (000 = disabled) into section [717]. Program the duration of the Keypad Lockout from 001 to 255 minutes into
section [716].
11.5 Battery Charge Current
Section [700]: General Options
Option [2] OFF = Battery Charge Current: 350mA (default)
Option [2] ON = Battery Charge Current: 700mA (40VA transformer required)
11.6 Partitioning
Section [700]: General Options
Option [1] OFF = Partitioning Disabled (default)
Option [1] ON = Partitioning Enabled
The MG5000 is equipped with a partitioning feature which can divide the alarm system into two distinct areas identified as
Partition 1 and Partition 2. Partitioning can be used in installations where shared security systems are more practical, such as an
office/warehouse building. When partitioned, each zone, each user code (see Access Codes on page 11) and some of the
system's features can be assigned to Partition 1, Partition 2 or both. If the system is not partitioned, all user codes and
features will be recognized as belonging to Partition 1.
Users can only arm partitions to which they have been assigned.
Only zones assigned to Partition 1 will arm/disarm when Partition 1 is armed or disarmed.
Only zones assigned to Partition 2 will arm/disarm when Partition 2 is armed or disarmed.
Zones assigned to both partitions will arm when both partitions are armed and will disarm when at least one disarms.
The following features can be programmed separately for each partition: Entry/Exit Delay Timer, Auto-arming Options, Bell
Cut-Off Timer, Switch to Stay arming, PGM Events and Account Numbers.
If the system is not partitioned, all zones, user codes, and features will be recognized as belonging to partition 1.
Zones that have been manually assigned to partition 2 will no longer function.