36 Reference & Installation Manual
9.11.2 Ademco Express
The Ademco Express is a high-speed reporting format, which will transmit the 2-digit (00 to FF) report codes programmed
into sections [860] to [876].
9.11.3 Ademco Contact ID
Ademco Contact ID is a fast communicator format that uses tone reporting instead of pulse reporting. This communicator
format also uses a pre-defined list of industry standard messages and report codes that will suit most of your basic
installation needs. Please refer to the Contact ID Report Codes List in the Programming Guide for a complete list of these
report codes and messages. If the reporting codes are set at 0xFF, the MG5000 will send the appropriate report code
from the Automatic Report Code List in the MG5000 Programming Guide. Alternatively, report codes can be
programmed using the Ademco Contact ID Report Codes in the MG5000 Programming Guide.
9.11.4 Event Call Direction
Section [802]: Options [1] to [3]; Arming/Disarming
Option [1] ON =Call MSTN 1
Option [2] ON =Call MSTN 2
Option [3] ON =Call Pager telephone number
Section [802]: Options [5] to [7]; Alarm/Alarm Restore
Option [5] ON =Call MSTN 1
Option [6] ON =Call MSTN 2
Option [7] ON =Call Pager telephone number
Section [803]: Options [1] to [3]; Tamper/Tamper Restore
Option [1] ON =Call MSTN 1
Option [2] ON =Call MSTN 2
Option [3] ON =Call Pager telephone number
Section [803]: Options [5] to [7]; Trouble/Trouble Restore
Option [5] ON =Call MSTN 1
Option [6] ON =Call MSTN 2
Option [7] ON =Call Pager telephone number
Section [804]: Options [1] to [3]; Special Reporting
Option [1] ON =Call MSTN 1
Option [2] ON =Call MSTN 2
Option [3] ON =Call Pager telephone number
Section [804]: Options [5] to [7]; Special Reporting
Option [1] ON =Call voice on zone alarm (burglary/fire)
Option [2] ON =Call voice on panic alarms
Option [3] ON =Call voice on paramedic alarm
The events are divided into six groups (see above) where each event group can be programmed to dial up to three
telephone numbers (MSTN 1 & 2 and the Pager telephone number).
When a reportable event occurs in the system, the Magellan console will begin dialing the numbers sequentially
starting from MSTN 1 (if enabled), skipping any disabled numbers and stopping once all selected telephone numbers
have been called. After a certain amount of failed attempts (section [837]) at trying to call the monitoring station, the
console will then dial the selected backup telephone number (if enabled; see Programming Guide).
If the Alternate Dial option is enabled, the console will dial the programmed backup telephone number (if enabled) after
every failed attempt. If no backup telephone number is programmed, the console will never report to the backup
telephone number.
Example: The system is armed and zone 1 has been breached causing an alarm. If options [5] and [7] are OFF and
option [6] is ON in section [802], the console will attempt to communicate with MSTN 2.
9.11.5 Account Numbers
Section [811]: Partition 1, Section [812]: Partition 2
All report codes are preceded by a 4-digit or 3-digit Partition Account Number to ensure correct identification in a
partitioned system. Partition account numbers can be any hexa-digit from 1 to F. To enter a 3-digit account number,
simply press the [
FORCE] key followed by a 3-digit account number. Also, when using 3-digit account numbers, you
must use 1-digit report codes.
9.12 Dialing Method
Section [800]: Dialer Options
Option [6] OFF = Pulse Dialing (see Pulse Ratio on page 37).
Option [6] ON = Tone/DTMF Dialing (default)