MG5000 17
5.1.17 24 Hr. Hold-up Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 17
When a 24Hr. Hold-up zone opens, whether it is armed or disarmed, the console will immediately generate an alarm.
This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See Alarm
Types on page 18. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as a
Hold-up alarm.
5.1.18 24 Hr. Gas Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 18
When a 24Hr. Gas zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. This
alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See Alarm Types
on page 18. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as a Gas alarm.
5.1.19 24 Hr. Heat Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 19
When a 24Hr. Heat zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. This
alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See Alarm Types
on page 18. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as a Heat
alarm.
5.1.20 24 Hr. Water Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 20
When a 24Hr. Water zone opens, whether it is armed or disarmed, the console will immediately generate an alarm.
This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See Alarm
Types on page 18. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as a
Water alarm.
5.1.21 24 Hr. Freeze Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 21
When a 24Hr. Freeze zone opens, whether it is armed or disarmed, the console will immediately generate an alarm.
This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See Alarm
Types on page 18. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as a
Freeze alarm.
5.2 Zone Definition Status
There are eight zone definitions that are affected by the Stay/Sleep alarm delay (section [720]). The following table shows how
the zone definition changes depending on the arm status and if the Stay/Sleep alarm delay is enabled. see Stay/Sleep Arm Alarm
Delay on page 32.
Table 4: Zone Definition Status
Stay/Sleep Alarm Delay Disabled -
Section [720] is 0
Stay/Sleep Alarm Delay Enabled -
Section [720] is not 0
Zone
Definition
Description Stay Arm Sleep Arm Fully Arm Stay Arm Sleep Arm Fully Arm
03 Entry Delay1/Stay/Sleep Not Armed Not Armed Entry Delay 1 Not Armed Not Armed Entry Delay 1
04 Entry Delay2/Stay/Sleep Not Armed Not Armed Entry Delay 2 Not Armed Not Armed Entry Delay 2
05 Follow (Entry Delay/Instant) As is As is As is Follow (Entry
Delay/
SleepDelay)
Follow (Entry
Delay/SleepDelay)
Follow (Entry
Delay/Instant)
06 Follow/Stay Not Armed Follow (Entry
Delay/Instant)
Follow (Entry
Delay/Instant)
Not Armed Follow (Entry
Delay/SleepDelay)
Follow (Entry
Delay/Instant)
07 Follow/Stay/Sleep Not Armed Not Armed Follow (Entry
Delay/Instant)
Not Armed Not Armed Follow (Entry
Delay/Instant)
08 Instant As is As is As is Sleep Delay Sleep Delay Instant
09 Instant/Stay Not Armed Instant Instant Not Armed Sleep Delay Instant
10 Instant/Stay/Sleep Not Armed Not Armed Instant Not Armed Not Armed Instant