MG5000 1
Part 1: Introduction
1.1 Features
Built-in transceiver: supports all existing Magellan transmitters including the MG-REM2 and MG-2WPGM.
32 zones (any of which can be wireless or keypad zones).
2 on-board hardwire zone inputs. 4 zones total with ATZ.
Supports 16 PGMs (any of which can be wireless).
32 users and 32 remote controls (one per user).
In-field upgradeable:
Update the MG5000’s firmware by connecting it to a PC via a 306USB Interface and then using the Winload software (V2.80 or
higher).
Menu-driven programming for the Installer, Master, and Maintenance codes. This enables you to program the MG5000
through a simple and easy to use interface, without the use of section numbers.
Multiple telephone numbers for event reporting:
Three for the monitoring station, five for personal dialing and one for pager reporting. Up to five persons can now be contacted
by the MG5000 in case of alarm.
Calendar with daylight savings time (section [730], option [1]):
You can now select 1 out of 18 different country groups each with its own preprogrammed local daylight savings time.
New Sleep arming method:
Similar to Stay arming, Sleep arming allows users to remain in a protected area, but provides a higher level of protection. For
example, in a two-story house, the perimeter is protected with Stay arming. With Sleep arming, the perimeter as well as the
main floor is protected (motion detectors, etc.), allowing you to roam the second floor and sleeping quarters.
Connect up to 15 hardwire keypads on the 4-wire communication bus.
Push button power reset:
Convenient reset button saves time when a momentary powerdown is required as opposed to having to physically disconnect
the control panel’s power cables. Press and hold the RESET switch for five seconds. The STATUS LED will start flashing.
Within 2 seconds of this flashing, press the reset switch again. The panel will reset to default and restart. Also, you can reset
all programmable sections to factory default values in section [950].
Available in 433MHz or 868MHz.
Supports Memory Key (PMC-3 and PMC-4).
RF jamming supervision (section [700], option [5]): The control panel will report a trouble if the RF signal is being jammed.
Supports SIA reporting format to central station.
1.2 Specifications
1.2.1 MG5000 Control Panel
AC Power: 16Vac transformer (refer to Table 1 on page 2) with minimum 20VA rating
(Rec. 40VA), 50 to 60Hz
Battery: 12Vdc, 4Ah/7Ah
•Aux. Power:
+
600mA typical, 700mA maximum, fuseless shutdown @ 1.1A
Bell Output:
++
1A, fuseless shutdown @ 3A
PGM Outputs: PGM1/PGM2 = 150mA low-current output
1.2.2 Magellan Keypads
Power input: Typically 9-16Vdc
Current Consumption MG32LED: 170mA, MG10LEDV/H: 95mA, MG32LRF: 40mA
1 standard keypad zone
On-board anti-tamper switch (optional)
Maximum Range Maximum run of wire is 230m (750 feet)
Specifications may change without prior notice
+
Cannot exceed 200mA for UL installations
++
Cannot exceed 1A for UL installations